Specializing in Ultrasonic Flowmeters, Sales & Rental
888-722-5543
Home Newsletter About Us Contact Us FAQ My Account  
Shopping Cart -  Items in cart: 0 | Total: $0.00 
 
Flowmeter Selection Guide
Shop by Rental
Shop by Technology
Ultrasonic Transit Time
Ultrasonic Doppler
Open Channel
Turbine
Magnetic
Level
Recorder
Data Logger
Used / Refurbished
Hand-Held Infrared Thermometer
PORTABLE POWERPACK 1500 WATTS
POWER SUPPLY 240/102 AC TO 24VDC 300 MA
PRESSURE TRANSMITTERM - 100 PSI
BATCH CONTROLLER-4/20MA INPUT
BATCH CONTROLLER - ENC
Sonic Coupling Compound
TIPPING BUCKET RAIN GAUGE, 8"
5/8"x3/4" C700 WATER METER
14W SOLAR PANEL
WS700 : COMPOSITE/DISCRETE WATER SAMPLER. PULSE INPUT
Ultrasonic Thickness Gauge
Shop by Application

 

WS700-4/20MA : COMPOSITE/DISCRETE WATER SAMPLER. 4/20MA INPUT MODULE

WS700

WS700-4/20MA : COMPOSITE/DISCRETE WATER SAMPLER. 4/20MA INPUT MODULE 4-20mA to Pulse Converter Module This module is for use with flow monitors that produce a 4-20mA output. There are two versions available, one that pulses every 15 minutes at 20mA (RG750) and one that pulses every 30 minutes at 20mA (RG755). Please specify the unit conversion that best suits your application

 

Composite/Discrete Water Samplers Specifications

Operating Temperature: 0° to +70°C
Size of unit: 22”H X 17"W X 9"D
Weight: 20lb (Shipping Weight 22lb)
Materials:
     Enclosure: Expanded UV protected PVC
     Bottle: 2.5 gallon Polyethylene
     Pickup Hose: 15' reinforced PVC 1/4" ID polyethylene flexible tubing section with intake strainer
     Pump Tubing: Norprene 1/4" ID, 7/16” OD
Sample Pump:
     Flow Rate: 1000 ml per minute at a 4 foot head
     Type: Peristaltic
     Maximum Lift: ~20 feet
Battery: Rechargeable 5 AH Gel Cell
Battery Life: ~1 hour, continuous pumping under load
     Standby: 3 months while still retaining enough power to run the pump to capacity
Start Delay: 16 time settings from 0 to 12 hours
Composite Interval: 15 time settings from 5 min. to 12 hours plus an External Trigger mode setting
Sample Size: 15 composite sample sizes from 50ml to 2 liters plus a Full Bottle discrete setting (Approximate sizes at 4 foot head)
External Trigger Input: 250mS minimum pulse width
     Switch closure or 4-24VDC
Pulse Output: 5VDC one-second pulse
     1000ohm output impedance
Bottle Switch Input: Switch closure Input
     Floating read switch in bottle
Rain and Water Sensors: Optional moisture sensors or switch closure inputs
Internal Fuse: 10A Slow-Blow
 

Purchase

Starting at $1,625.00
 

Features


  • Ideal for wastewater, industrial and
        environmental sampling
  • CE Certified
  • Does composite, or discrete sampling
  • Simple to operate – no programming 
        required


  • Output provided for use with optional
        datalogger
  • Lightweight and easy to carry
  • Rugged construction for harsh environments
  • Meets federal, state and local wastewater 
        regulations
  • Timed and external flow pulsed samples
  • Adjustable and repeatable sample volume
  • Peristaltic pump prevents sample
        contamination
  • Automatic backflush clears pickup strainer
        and hose
  • Rechargeable battery or AC powered
  • Resources

    Printable Product Page
    Manual
    Terms
    Application Notes
    Flowmeter Selection Guide
    The Flow Surveyor's Guide
    Software
     

    Pricing and Configurations

    WS700
    WS700-4/20MA : COMPOSITE/DISCRETE WATER SAMPLER. 4/20MA INPUT MODULE
     
    WS700 : COMPOSITE/DISCRETE WATER SAMPLER. 4/20MA INPUT.
    4-20mA to Pulse Converter Module
    This module is for use with flow monitors that produce a 4-20mA output. There are two versions available, one that pulses every 15 minutes at 20mA (RG750) and one that pulses every 30 minutes at 20mA (RG755). Please specify the unit conversion that best suits your application

    Composite/Discrete Water Samplers Specifications

    Operating Temperature: 0° to +70°C
    Size of unit: 22”H X 17"W X 9"D
    Weight: 20lb (Shipping Weight 22lb)
    Materials:
    Enclosure: Expanded UV protected PVC
    Bottle: 2.5 gallon Polyethylene
    Pickup Hose: 15' reinforced PVC 1/4" ID polyethylene flexible tubing section with intake strainer
    Pump Tubing: Norprene 1/4" ID, 7/16” OD
    Sample Pump:
    Flow Rate: 1000 ml per minute at a 4 foot head
    Type: Peristaltic
    Maximum Lift: ~20 feet
    Battery: Rechargeable 5 AH Gel Cell
    Battery Life: ~1 hour, continuous pumping under load
    Standby: 3 months while still retaining enough power to run the pump to capacity
    Start Delay: 16 time settings from 0 to 12 hours
    Composite Interval: 15 time settings from 5 min. to 12 hours plus an External Trigger mode setting
    Sample Size: 15 composite sample sizes from 50ml to 2 liters plus a Full Bottle discrete setting (Approximate sizes at 4 foot head)
    External Trigger Input: 250mS minimum pulse width
    Switch closure or 4-24VDC
    Pulse Output: 5VDC one-second pulse
    1000ohm output impedance
    Bottle Switch Input: Switch closure Input
    Floating read switch in bottle
    Rain and Water Sensors: Optional moisture sensors or switch closure inputs
    Internal Fuse: 10A Slow-Blow
    Price: $1,625.00